How accurate are thermocouples?

 Accuracy of Thermocouples in Temperature Measurement

thermocouple imageA thermocouple is a widely used temperature sensor device that measures temperature across a broad range of applications, including scientific, industrial, and household settings. While thermocouples are generally accurate, their precision can degrade over time due to environmental factors. The accuracy of a thermocouple is influenced by several variables, such as the composition of its alloys, the measured temperature, sensor construction, sheath material, the medium being measured, and the state of the medium (solid, liquid, or gas). Additionally, the diameter of the thermocouple wire, whether exposed or sheathed, plays a significant role in its accuracy.

Principle of Operation

James at work 2 scaled imageThermocouple’s function based on the Seebeck effect, which describes the voltage generated when two dissimilar metals form an electrical circuit. A thermocouple consists of two metal wires joined at one end, referred to as the “hot” or measuring junction, which is exposed to the substance whose temperature is being measured. The other ends of the wires, known as the “cold” or reference junction, are connected to a medium with a known temperature and linked to copper wires that transmit the signal to a meter or display.

The voltage generated along the thermocouple wires is not confined to the junction itself but is distributed across the entire length of the wires between the hot and cold junctions. Accurate temperature measurements rely on the homogeneity of the thermocouple wires—meaning that the wires must maintain a uniform and consistent composition throughout their length.

Factors Affecting Accuracy

In industrial environments, thermocouple wires may lose their homogeneity over time due to chemical exposure, mechanical damage (e.g., bending), or prolonged exposure to high temperatures. Certain thermocouple materials are more susceptible to alterations when exposed to temperatures exceeding 200°C. Any variation in wire homogeneity can cause an altered voltage output, leading to measurement errors. Regular calibration is essential to maintaining the accuracy of thermocouples.

Calibration and Performance Considerations

Screenshot 2022 09 29 114227 imageAll thermocouples are subject to calibration drift over time; the extent and rate of drift depend on operating conditions. The performance of a thermocouple is critically dependent on the uniformity of its physical and chemical properties along its entire circuit. While thermoelement materials are manufactured with strict quality control to ensure uniformity, variations occur during use due to differential exposure to heat and chemicals, leading to physical and structural changes in the wire. These changes can cause deviations in the thermoelectric electromotive force (EMF), which, in turn, affect the accuracy of temperature readings.

Calibration involves comparing a thermocouple’s readings to a reference standard with a known accuracy. By determining the error margin of the thermocouple, appropriate corrections can be applied to temperature readings. While laboratory calibration is conducted under controlled conditions, field calibration provides a practical method for verifying measurement accuracy in real-world applications. Regular calibration is crucial for maintaining precise, repeatable, and high-quality temperature measurements. Industry experts, such as Pyrosales, recommend calibrating thermocouples at least once every 12 months.

Comparison of Thermocouples and RTDs

Screenshot 2021 12 13 130331 imageBoth thermocouples and resistance temperature detectors (RTDs) serve as effective temperature sensors. However, RTDs typically offer higher accuracy within their operational temperature range, as platinum—the primary material in RTDs—is more stable than most thermocouple materials. Additionally, RTDs utilize standard instrumentation wire, which can reduce installation costs.

Despite their lower cost and broader temperature range, thermocouples have advantages over RTDs in certain applications. They are more durable in high-vibration environments or where mechanical shock is a concern. Additionally, thermocouples can be designed with smaller dimensions, allowing for more flexible application in constrained spaces. Their ability to withstand higher temperatures and be customized for specific applications makes thermocouples a valuable choice in many industrial processes.

Conclusion

Thermocouples remain an essential tool for temperature measurement across various industries. Ensuring their accuracy requires an understanding of their operating principles, potential sources of measurement error, and the importance of regular calibration. By adhering to best practices in thermocouple selection, installation, and maintenance, users can achieve reliable and precise temperature measurements tailored to their specific application needs.